Specifications |
|
Analog Inputs |
|
|
Frequency Response |
20 Hz – 20 kHz, ± 0.5 dB. |
|
Channel Separation |
> 111 dB @ 1 kHz, +24 dBu. |
|
Connectors |
3.5 mm Phoenix® connectors. |
|
Number of Inputs |
Four (4) switchable balanced mic or line level. |
|
Nominal Input Level |
+4 dBu with 20 dB of headroom. |
|
Maximum Input Level |
+23 dBu. |
|
Mic pre-amp gain |
0, 11.8, 24, 44 or 54 dB switchable. |
|
Mic pre-amp EIN |
< -127dB with 150 ohm source impedance. |
|
CMRR |
> 76 dB @ 1 kHz, unity gain. |
|
Input impedance |
8k Ohms balanced, 4k Ohms unbalanced. |
|
Phantom power (per input) |
+48 VDC @ 10 mA maximum. |
|
Dynamic range |
> 116 dB, A-weighted. |
|
THD + Noise |
< -100 dB, unweighted; 1 kHz @ +22 dBu with 0 dB gain. |
|
Latency |
0.28 mS |
|
Analog Outputs |
|
|
Frequency Response |
20 Hz – 20 kHz, ± 0.5 dB. |
|
Channel Separation |
> 111 dB @ 1 kHz, +24 dBu. |
|
Connectors |
3.5 mm Phoenix® connectors. |
|
Number of outputs |
Four (4) balanced line level. |
|
Nominal output level |
+4 dBu with 20 dB of headroom. |
|
Maximum output level |
+24 dBu (+22.8 dBu into a 2k Ohm minimum load). |
|
Output impedance |
300 Ohms balanced, 150 Ohms unbalanced. |
|
Dynamic range |
> 118 dB, A-weighted. |
|
THD + Noise |
< -105 dB, unweighted; 1 kHz @ +22 dBu with 0 dB gain. |
|
Latency |
0.60 mS |
|
Mechanical |
|
|
Space Required |
Half rack unit (WDH: 20.83 cm x 22.86 cm x 4.37 cm / 8.2 in. x 9 in. x 1.72 in.) Depth does not include connector allowance. Allow at least 3 inches additional clearance for rear panel connections. Additional depth may be required depending upon your specific wiring and connections. |
|
Electrical |
PoE IEEE 802.3af Class 0, 10 Watts maximum. No line voltage switching required (100-250 VAC, 50-60 Hz). |
|
Ventilation |
Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed (5.08 cm, 2 in minimum clearance). The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc. |
|
Certifications or Compliance |
UL 60065, cUL 60065, IEC 60065, FCC 15.109:2015, FCC 15.109(g):2015, FCC 15.107:2015, (CISPR 32), EN 55032:2012, EN 55103-2:2009, EN 61000-3-3:2013, EN 61000-3-2:2006, ICES-003:2012, RoHS |
|
System |
|
|
Sampling Rate |
48 kHz, ± 100 ppm. |
|
Dante Cable |
Standard CAT6, maximum device-to-device length = 100 meters |