Konvision CR-250-RH-CR-100 - Bundle: CR250 & CR100

1039146

Neuf

The combination of accurarcy of CR-250 spectroradiometer and the excellent measurement speed...
Lire la suite
Prix constructeur :
17 400,00 CHF HT

Prix Visuals :

15 660,00 CHF


16 928,46 CHF TTC  

Rectangle
Garantie : garantie Garantie Visuals 24 mois
Service interne : révision, réparation & backup.

Disponibilité : clock Délai habituel entre 2 et 4 semaines

- +

1039146
En savoir plus  
CR-100&CR-250-RH Package Chroma Meter & Spectroradio Meter


The combination of accuracy of CR-250 spectroradiometer and CR-100 the excellent measurement speed as well as the dark part measurement characteristics will help to achieve an ideal result of maonitor color correction,compatible with color management softwares such as Lightspace and Calman.Colorimetry Research CR-100,high quality chroma meter.

CR-100 applies all-metal aluminum and stainless steel structure ensures an excellent durability,compact and only 340 grams lightweight design.Using tri-color stimulus filter and four-color matrix algorithm to improve the color measurement accurary with 380–780 nm wavelength range,compatible with color management softwares such as Lightspace and Calman.


 
 

Specfications



 



Portable Recorder



Weight


1.0 oz.0.45kg

Wavelength range



380  –  780 nm


Brightness range 0.0002 fL-1500 fL

0.0002 fL @Signal to noise ratio > 10, 20s exposure

0.001 fL @Signal to noise ratio > 10, 0.5s exposure

0.001 fL @Signal to noise ratio > 100, 20s exposure

1500 fL @Signal to noise ratio > 8000, 1s exposure
Brightness Accuracy ± 2 % @ 0.1 fL, 0.4s exposure
Brightness Repeatability 0.2 % @ 0.1 fL, 0.4s exposure

1.5 % @ 0.01 fL, 0.5s exposure

1.5 % @ 0.001 fL, 20s exposure
Brightness range 0.17cd/ - 154,000cd/㎡(0.05 fL-45000 fL
Chroma Accuracy ± 0.0015 x, y @ 0.1 fL, 0.4s exposure

± 0.0015 x, y @ 0.02 fL, 20s exposure        

Chroma Repeatability


0.0005 x, y @ 0.1 fL, 0.4s exposure

0.0005 x, y @ 0.02 fL, 20s exposure
Polarization Error

≤0.1

 


Sync Frequency 10 – 500Hz (Custom sync frequency10Hz
Sync Frequency

Direct observation and measurement system



Exposure Time Range



1ms - 20s

 



Voltage


5V/120 mA (600mW) via USB 2.0
Interface USB 2.0

 
Weight 12oz. (0.34 Kg.)

Observation Optics



Patent-pending for movable and rotatable view system



Custom Sync


10 – 10000 Hz

Exposure Time Range


0.04 - 30s

Voltage


15V/120 mA600 mWvia USB 2.0

Interface


USB 2.0

Weight


2.5 oz.1.134 kg

 



 



    Besoin d'aide,
    Besoin d'un financement,
    Appellez-nous !

  • GE : + 41 22 561 07 07
  • ZH : + 41 43 255 59 00
  • TI   : + 41 91 985 25 11